TYPE:JC660

NAME:JC660 Anti-explosion Pressure Transducer

JC660 series of anti-explosion pressure transducer is specially designed for high-explosion dangerous site. It can provide stable and accurate measurement at an absolute pressure, gauge pressure and differential pressure of liquid or gas medium from -100KPa to 200MPa.

JC660 Anti-explosion Pressure Transducer

●Product Overview

JC660 series of anti-explosion pressure transducer is specially designed for high-explosion dangerous site. It can provide stable and accurate measurement at an absolute pressure, gauge pressure and differential pressure of liquid or gas medium from -100KPa to 200MPa. It welds the existing multi -crystalline silicon film sensing element of HELM with the enclosure using welding technology and can be customized rapidly according to the regulations to meet the individualized needs of different users. With built-in amplification circuit and diversified structural forms, it can be equipped with M 20 x 1.5 or G1 / 2 internal thread explosion-proof flexible tube connector. Featured by good performance, small size and flexible design, JC660 series anti-explosion pressure transducer has the advantages of a very high ratio of performance to cost and long service life compared with traditional explosion-proof transducers. It is widely used in oilfield, mining well, chemical, electric power, boiler, natural gas and other fields.
JC660 – E type pressure transducer is an intrinsically safe explosion-proof pressure transducer, with explosion- proof marking of Ex iaⅡCT6 and explosion-proof conformity certificate number of CNEx07.0988. It boasts stable and reliable performance supporting the use of repetitive-use type safety energy limiter or safety barrier.
JC660 – D type pressure transducer is a flameproof pressure transducer, with explosion – proof marking of Ex dⅡCT6 and explosion-proof conformity certificate number of CNEx08.2405.
JC660 – ED type is an intrinsically safe flameproof pressure transducer, with explosion -proof marking of Ex iaⅡCT6 and Ex dⅡCT6. It is safe and reliable and simple and convenient to operate, without the installation of safety barrier when installed and used.

●Product Features

* Intrinsically safe and flameproof certification: Ex iaⅡCT6, Ex dⅡCT6
* Measuring range: -100KPa~0~200Pa…100KPa…200MPa
* Gauge pressure, absolute pressure and differential pressure are available
* Adoption of explosion-proof genuine HELM multi – crystalline silicon film chip, with stable and reliable performance and long service life
* Reverse polarity and over-voltage protection of power supply
* Explosion – proof design, safe and reliable
* Strong anti-interference and immunity to vibration and excellent long -term stability

 

●Outline Drawing

Measuring range -100KPa~0~200Pa…5KPa…200MPa
Overload capacity Two times FS pressure (1.1 times FS pressure for 100MPa product)
Pressure type Gauge pressure, absolute pressure, differential pressure
Measured medium Gas or liquid compatible with 316 stainless steel
Overall accuracy(Non-linearity, repeatability, lagging) ±0.1%FS ±0.25%FS ±0.5%FS
Long-term stability Typical: ±0.1%FS/ year Maximum: ±0.2%FS/ year
Zero point temperature drift Typical: ±0.02%FS/℃ Maximum: ±0.05%FS/℃
Sensitivity temperature drift Typical: ±0.02%FS/℃ Maximum: ±0.05%FS/℃
Operating temperature -20~ 85℃
Compensation temperature -20 ~60℃
Range of power supply 12~36VDC (24VDC generally)
Signal output 4~20mA/1~5VDC/0~5VDC
Load resistance ≤(U-12)/0.02  Ω
Insulation resistance ≥2000MΩ(testing condition100VDC)
Resolution Infinite small (theoretical) 1 / 100000 (general)
Response time ≤1 ms
Influence of vibration Within mechanical vibration frequency 20Hz ~ 1000Hz, change of output is less than 0.1% FS
Weight Approx. 0.5kg

 

●Tips of Selection
1.The measured medium shall be compatible with the material contacting with the product.
2.The code E, an additional function code for selection, namely, intrinsically safe explosion-proof Ex iaIICT6 must be power supplied via safety barrier.
3.The code D, an additional functional code for selection, namely, flameproof Ex dIICT6 is preferably provided with explosion – proof flexible hose for the electrical power cable connected at the rear side.
4.The options W1 and W2 are general structural encapsulation and only used for HM60 – E intrinsically safe explosion-proof pressure transducer.
5.It is unnecessary to install safety barrier on HM60 – ED intrinsically safe flameproof pressure transducer during system use.
6.Please contact us for other special requirements and clearly indicate them in the order.