JC30 Air Pressure/ Micro Differential Pressure Transmitter Description:

JC30 air pressure/ micro differential pressure transmitter is an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance. It is rugged and durable to meet the requirements of more stringent industrial standards. It is widely used in industrial support, industry support and equipment support. The series includes a variety of options, which are applied to different industries and different working conditions. It solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.

JC30 air pressure/ micro differential pressure transmitter adopts new technology to produce micro range, high stability silicon piezoresistive non-oil-filled sensor components and special digital integrated circuits. It is firmly packaged with 304 stainless steel casing through stress isolation technology. The measured air pressure or differential pressure enters the positive and negative pressure chamber of the sensor through the G1/4 external thread or φ6 integrated barbed tower pressure interface, and the corresponding air pressure or differential pressure is converted into a plurality of industrial standard signal outputs proportional to the sensor detection, Such as 4 ~ 20mA, 0-5V DC, 0.5-4.5V DC.

JC30 Air Pressure/ Micro Differential Pressure Transmitter Features:

* Measuring range: 0~100Pa…100KPa
* All stainless steel construction, compact and durable, easy to install
* Temperature range is -20~100°C
* Wind pressure, differential pressure two kinds of structural interoperability design
* Accuracy 1-2% FS for pressure below 250Pa, accuracy 0.5% of industry standard FS for other ranges
* Reliable quality and cost-effective

JC30 Air Pressure/ Micro Differential Pressure Transmitter Application

* HVAC
* Energy Management System
* VAV and fan control
* Environmental pollution control
* Clean room, clean room project
* Oven pressurization and furnace ventilation control
* Monitoring of natural gas and gas pipeline network
* Downhole ventilation test
* Pharmaceutical equipment and medical equipment
* Filter pressure
* Building exhaust system

Size and Outline:

JC30 Air Pressure/ Micro Differential Pressure Transmitter

Note: Mark A on the drawing, balance the atmospheric pressure hole when measuring the wind /air pressure, avoid plugging, such as water inlet, dust, etc., connect the B connection when measuring the differential pressure, as the differential pressure measurement negative pressure port,a differential pressure is formed with the positive pressure port below the vertical , as shown in the W3/W4 outline drawing

Electrical Connections:

Description PG7 Grand lock head outlet
1m Shielded cable
A type Hessman Plug M12x1 Aviation plug
Straight out or Corner out 1m unshielded cable
Code W1 W2 W3/W4
Diagram JC30 Air Pressure/ Micro Differential Pressure Transmitter JC30 Air Pressure/ Micro Differential Pressure Transmitter JC30 Air Pressure/ Micro Differential Pressure Transmitter
Protection Grade IP67 IP65 IP67
Ambient Temperature -40~85℃ -40~85℃ -40~85℃
Current output wiring definition RED:V+
BLUE:OUT+
1#:V+
2#:OUT+
BROWN(1#):V+
BLUE(3#):OUT+
Voltage output wiring definition RED:V+
BLUE:OUT+
YELLOW:GND
1#:V+
2#:OUT+
3#:GND
BROWN(1#):V+
BLUE(3#):OUT+
BLACK(4#):GND
Current output wiring diagram JC30 Air Pressure/ Micro Differential Pressure Transmitter
Voltage output wiring diagram JC30 Air Pressure/ Micro Differential Pressure Transmitter

Performance Parameter:

Measuring Range 0~100Pa…100KPa
Overload Capability 1.5~2 times full-scale pressure
Burst Pressure 4xFS
Durability ﹥1×107 cycle(P:0~FS)
Pressure Type Gauge / Absolute
Measuring medium Dry clean gas compatible with 304 stainless steel
Response time ≤4ms
Resolution Minimum. 0.5Pa
Accuracy (linear,hysteresis, repeatability) Typical:±0.5%FS
Typical:±1%FS(below 250Pa)
Maximum:±1%FS
Maximum:±2%FS(below 250Pa)
Long-term stability Typical:±0.2%FS/year Maximum:±0.3%FS/year
Zero temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃
Sensitivity temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃

Environmental Conditions:

Medium Temperature -40~100℃
Ambient Temperature -40~85℃
Compensation Temperature -20~80℃
Vibration resistance 10g             IEC 60068-2-6
Impact resistance 100g/1ms       IEC 60068-2-27
EMC- launch EN61000-6-3
EMC- anti-interference EN61000-6-2
Insulation resistance ﹥100MΩ/100V
Shell Protection Plug type(IP65);  Cable type(IP67)   Compliance IEC 60529 standard
Certification CE

Electrical Specifications:

Code Standard signal (with short circuit protection) Supply voltage with polarity protection Power supply- Current Load(R) Output Impendence
A1 4~20mA DC 9~30V Max.25mA R≤(U-9)/0.02Ω
V1 1~5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V2 0~5 V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V3 0.5~4.5V DC DC 9~30V 8mA R≥50kΩ <2kΩ
V4 0.5~4.5V DC DC 5±0.25V 8mA R≥50kΩ <2kΩ

Material:

Interface and housing Stainless Steel 304L
O-ring Silicone Rubber
Sensor Diaphragm Silicon wafer(measured dry ,dust-free, non-corrosive or weakly corrosive, clean gas)
Weight Approx.150g
JC30 G 01KN A1 F2 W2
Model Pressure  type Pressure Range Output Mounting thread Electrical connections
JC30

 

 

 

 

G=Gauge or wind/air pressure
D=Differential Pressure
002C= ±200Pa  G/D
005C= ±500Pa  G/D
01KC= ±1KPa  G/D
02KC= ±2KPa  G/D
05KC= ±5KPa  G/D
10KC= ±10KPa G/D
005N= -500Pa  G/D
01KN= -1KPa  G/D
02KN= -2KPa  G/D
05KN= -5KPa  G/D
10KN= -10KPa  G/D
20KN= -20KPa  G/D
002P= 200Pa  G/D
005P= 500Pa  G/D
01KP=1KPa  G/D
02KP= 2KPa  G/D
05KP= 5KPa  G/D
10KP= 10KPa  G/D
20KP= 20KPa  G/D
40KP= 40KPa  G/D
001B= 100KPa  G/D
A1=4~20mA
V1=1~5V
V2=0~5V
V3=0.5~4.5V
V4=0.5~4.5V/5V
F1=M20x1.5male
F2=G1/4male
F5=Ф8 gas nozzle
F0= Customize
W1=Straight Out 1m
W2=A type HSM plug
W3=M12 corner out 1m
W4=M12 Straight Out 1m

Model example: JC30G01KNA1F2W3
(JC30 Air Pressure/ Micro Differential Pressure Transmitter; Range 0~1MPa Gauge; Output 4~20mA; Accuracy 0.5% typical; Power Supply 9~30VDC;Pressure Connection G1/4 male thread; Electrical Connection M12 corner out 1m; Selection Remarks: The range meter 01KP=1KPa G/D G indicates the gauge pressure or wind/air pressure, which is the pressure difference with the atmosphere, that is, the wind pressure measurement of a single pressure port, D is the differential pressure measurement, measuring the pressure difference between the two pressure ports. Use the B-copper joint in the outline drawing to connect the negative pressure port, as shown in the outline drawing.

Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the salesengineers for details.