• JC29 RS485/CAN Digital Pressure Transmitter
  • JC29 RS485/CAN Digital Pressure Transmitter
  • JC29 RS485/CAN Digital Pressure Transmitter
  • JC29 RS485/CAN Digital Pressure Transmitter

TYPE:JC29

NAME:JC29 RS485/CAN Digital Pressure Transmitter

JC29 RS485/CAN digital pressure transmitter is an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance.

JC29 RS485/CAN Digital Pressure Transmitter Description:

JC29 RS485/CAN digital pressure transmitter is an industrial measuring instrument that is modular in design and meets global OEM standards. The series is stable and reliable, and has excellent cost performance. It is rugged and durable to meet the requirements of more stringent industrial standards. It is widely used in industrial support, industry support and equipment support. The series includes a variety of options, which are applied to different industries and different working conditions. It solves the needs for economic pressure monitoring in different occasions and serves a wide range of industries.

JC29 RS485/CAN digital pressure transmitter features a low power, wide voltage design. The power consumption is not more than 2 mA without digital communication. The power supply range is 3.3V ~ 16V and 12 ~ 30V (typically 24V). It can be powered by solar energy or battery, or it can be powered by 24VDC in industrial field. Good compatibility with industrial networking, through low-voltage electrical EMC testing (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5). RS485 digital pressure sensor communication adopts RS485 communication protocol, half-duplex working mode, communication speed is 57600BPS. Easy to use with a simple MODBUS RTU command format. The sampling speed is 8-10 times/s and can be expanded by 400 times/s. The transmitter can form a twisted pair network via RS485 bus, which is especially suitable for computer control.

JC29 RS485/CAN Digital Pressure Transmitter Features:

* Measuring range: 0~10KPa……100MPa
* Stainless steel isolation diaphragm integrated structure, can adapt to harsh environment
* Good compatibility and interchangeability
* Standard MODBUS RTU communication protocol / CAN Open or custom protocol, J1939 protocol
* User can change the communication address, communication baud rate can be set
* The power supply range is 3.3V ~16V and 12 ~ 30V (typically 24V), which meets low power consumption or industry standards.
* Small size, high cost performance, high stability, long product life and durability
* Remote zero calibration and zero trimming
* With strong resistance to shock, vibration and electromagnetic interference

JC29 RS485/CAN Digital Pressure Transmitter Application:

* Building automation, constant pressure water supply system
* Hydraulic and pneumatic control systems
* Power station operation inspection, locomotive brake system
* Petrochemical, environmental protection, power industry pressure network configuration acquisition
* Collection of pressure network configuration for smart city pipe network, oil field pipeline and large and small hydropower stations
* Pressure network configuration collection of heating, fire hose network and fire equipment, medical equipment
* Pressure network configuration acquisition of special equipment, special vehicles and equipment, such as industrial robots, test benches, remote control test equipment, etc.

Size and Outline:

JC29 RS485/CAN Digital Pressure Transmitter

Electrical Connections:

Description PG7 Grand lock head outlet
1m Shielded cable
A type Hessman Plug M12x1 Aviation plug Straight out or
Corner out 1m unshielded cable
Code W1 W2 W3/W4
Diagram JC29 RS485/CAN Digital Pressure Transmitter JC29 RS485/CAN Digital Pressure Transmitter JC29 RS485/CAN Digital Pressure Transmitter
Protection Grade IP67 IP65 IP67
Ambient Temperature -40~85℃ -40~85℃ -40~85℃
485 output wiring definition RED:V+
BLACK:V-
BLUE:RS485A
YELLOW:RS485
1#:V+
2#:V-
3#: RS485A
4#: RS485B
BROWN(1#):V+
BLACK(2#):V-
BLUE(3#):RS485A
WHITE(4#):RS485B
CAN output wiring definition RED:V+
BLACK:V-
BLUE:CAN-High
YELLOW: CAN-Low
1#:V+
2#:V-
3#: CAN-High
4#: CAN-Low
BROWN(1#):V+
BLACK(2#):V-
BLUE(3#): CAN-High
WHITE(4#): CAN-Low
485
output wiring diagram 
JC29 RS485/CAN Digital Pressure Transmitter
CAN output wiring diagram JC29 RS485/CAN Digital Pressure Transmitter

Performance Parameter:

Measuring Range 0~10KPa…100MPa
Overload Capability 1.5~2 times full-scale pressure
Burst Pressure 4xFS(≤110MPa)
Durability ﹥1×107 cycle(P:10~90%FS)
Pressure Type Gauge / Absolute
Measuring medium Gas or liquid compatible with 316 stainless steel
Response time ≤50ms
Resolution 0.01%FS
Baud rate(customer can modify) 9600(Default)A variety of baud rates are available as 2400,4800,19200,38400,
Address(customer can modify) 01(Default)
Accuracy (linear,hysteresis, repeatability) Typical:±0.5%FS Maximum:±1%FS
Long-term stability Typical:±0.2%FS Maximum:±0.3%FS
Zero temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃
Sensitivity temperature drift Typical:±0.02%FS/℃ Maximum:±0.05%FS/℃

Environmental Conditions:

Medium Temperature -20~85℃
Ambient Temperature -20~80℃
Compensation Temperature -10~60℃
Vibration resistance 10g             IEC 60068-2-6
Impact resistance 500g/1ms      IEC 60068-2-27
EMC test Static electricity, radio frequency,pulse,surge EN61000-4-2、EN61000-4-3、 EN61000-4-4、 EN61000-4-5
Insulation resistance ﹥100MΩ(100V)
Shell Protection Plug type(IP65);  Cable type(IP67)   Compliance IEC 60529 standard
Certification CE

Electrical Specifications:

Code Communication method Communication Protocol Power Supply Working Current
S1 RS485 bus MODBUS RTU 3.3~16VDC <5mA(max)(customizable <2 mA)
12~30V(typical 24V) <10mA(max)
C1 CAN bus CAN customize 12~30V(typical 24V) <10mA(max)
C2 CAN bus CAN open 12~30V(typical 24V) <10mA(max)

Material:

Interface and housing Stainless Steel 304L
O-ring Fluororubber
Sensor Diaphragm Stainless Steel 316L
Weight Approx.180g
JC29 G 010B S1 D1 F2 W3
Model Pressure Type Pressure Range Output Power Supply Mounting thread Electrical connections
JC29

 

 

 

 

 

G=Gauge
A=Absolute
010K =10KPa G
020K =20KPa G
035K =35KPa G
070K=70KPa G
001B=1bar G/A
002B=2bar G/A
004B=4bar G/A
006B=6bar G/A
010B=10bar G/A
016B=16bar G/A
025B=25bar G/A
040B=40bar G/A
060B=60bar G
100B=100bar G
160B=160bar G
250B=250bar G
400B=400bar G
600B=600bar G
01KB=1000bar G
S1=RS485
Modbus RTU
C2=CAN Customize C2=CAN open
D1=12~36V D2=3.3~16V

 

F1=M20x1.5
male
F2=G1/4 male
F3=1/4NPT
F0= Customize
W1=Straight Out 1m
W2=A type HSM plug
W3=M12 corner out 1m
W4=M12 Straight Out 1m

Model example: JC29G010BS1D1F2W3
(JC29 RS485/CAN Pressure Transmitter; Range 0~1MPa Gauge; Output RS485; Accuracy 0.5% typical; Power Supply 24VDC;Pressure Connection G1/4 male thread; Electrical Connection M12 corner out 1m, Special instruction: 010B=10bar G/A, G/A stands for gauge and absolute pressure, G gauge, A absolute)

Remarks: It can be customized if the order quantity exceeds a certain amount. Please contact the sales engineers for details.